Malestorm's ABB Electrical Installtion Handbook PDF

By Malestorm

ISBN-10:

ISBN-13: 1301301301001

ISBN-10: 6086511993

ISBN-13: 9786086511999

ISBN-10: 6100812002

ISBN-13: 9786100812002

Show description

Read Online or Download ABB Electrical Installtion Handbook PDF

Best technique books

75 Years of Aerospace Research in the Netherlands. 1919 - - download pdf or read online

One other ebook entitled '75 Years of Aerospace study within the Netherlands', written in English, unfolds the historical past of the NLR and it really is predecessors. It was once released in 1994 and is out of print for a very long time now, yet made to be had back in electronic shape on the web site of the NLR old Museum.

Download PDF by F. Porges: Design of Electrical Services for Buildings

An outstanding book,even although written like a unique. strong images for illustrations. desire labored on examples for additional representation. connection with at the moment used desktop programs to automate lots of the repetative calculations lacking.

Additional info for ABB Electrical Installtion Handbook

Sample text

8 s for cold trip. For fault current values higher than 1600 A, the circuit-breaker trips instantaneously through magnetic protection. 2 Trip curves of electronic releases PR221 Introduction The following figures show the curves of the single protection functions available in the electronic releases. The setting ranges and resolution are referred to setting operations to be carried out locally. 2 Trip curves 3 General characteristics 3 General characteristics Trip curve electronic releases Trip curve electronic releases T4 250/320 T5 400/630 T6 630/800/1000 PR222DS/P PR222DS/PD PR223DS T4 250/320 T5 400/630 T6 630/800/1000 PR222DS/P PR222DS/PD PR223DS 104 0,4-0,42-0,44-0,46-0,48-0,5-0,52-0,54-0,56-0,58-0,6-0,62-0,64-0,66-0,680,7-0,72-0,74-0,76-0,78-0,8-0,82-0,84-0,86-0,88-0,9-0,92-0,94-0,96-0,98-1 0,18 (1) 0,4 1,2 1,8 2,4 1 3 3,6 4,2 5,8 6,4 7 7,6 8,2 8,8 9,4 10 5,5 2,5 3 4 0,6 102 L-S-I Functions (I2t const = OFF) 6,5 4,5 7 5 0,4-0,42-0,44-0,46-0,48-0,5-0,52-0,54-0,56-0,58-0,6-0,62-0,64-0,66-0,680,7-0,72-0,74-0,76-0,78-0,8-0,82-0,84-0,86-0,88-0,9-0,92-0,94-0,96-0,98-1 0,18 (1) 103 103 L-S-I Functions (I2t const = ON) t [s] 104 0,4 1,8 2,4 3 3,6 4,2 5,8 6,4 1 2,5 t [s] 3 7 7,6 8,2 8,8 9,4 10 5,5 6,5 4 4,5 5 7 102 7,5 7,5 8 8 9 9,5 1,5 10 1,2 0,6 9 9,5 1,5 10 10,5 10,5 12 I2t ON 1 12 102 T4 10-3 10-1 1 10 x In 1 T6 T5 T5 T6 400 630 630 800 1000 10 I [kA] Note: The dotted curve of function L corresponds to the maximum delay (t1) which can be set at 6xl1, in the case where 320 A CTs are used for T4 and 630 A for T5.

For fault current values higher than 1600 A, the circuit-breaker trips instantaneously through magnetic protection. 2 Trip curves of electronic releases PR221 Introduction The following figures show the curves of the single protection functions available in the electronic releases. The setting ranges and resolution are referred to setting operations to be carried out locally. 2 Trip curves 3 General characteristics 3 General characteristics Trip curve electronic releases Trip curve electronic releases T4 250/320 T5 400/630 T6 630/800/1000 PR222DS/P PR222DS/PD PR223DS T4 250/320 T5 400/630 T6 630/800/1000 PR222DS/P PR222DS/PD PR223DS 104 0,4-0,42-0,44-0,46-0,48-0,5-0,52-0,54-0,56-0,58-0,6-0,62-0,64-0,66-0,680,7-0,72-0,74-0,76-0,78-0,8-0,82-0,84-0,86-0,88-0,9-0,92-0,94-0,96-0,98-1 0,18 (1) 0,4 1,2 1,8 2,4 1 3 3,6 4,2 5,8 6,4 7 7,6 8,2 8,8 9,4 10 5,5 2,5 3 4 0,6 102 L-S-I Functions (I2t const = OFF) 6,5 4,5 7 5 0,4-0,42-0,44-0,46-0,48-0,5-0,52-0,54-0,56-0,58-0,6-0,62-0,64-0,66-0,680,7-0,72-0,74-0,76-0,78-0,8-0,82-0,84-0,86-0,88-0,9-0,92-0,94-0,96-0,98-1 0,18 (1) 103 103 L-S-I Functions (I2t const = ON) t [s] 104 0,4 1,8 2,4 3 3,6 4,2 5,8 6,4 1 2,5 t [s] 3 7 7,6 8,2 8,8 9,4 10 5,5 6,5 4 4,5 5 7 102 7,5 7,5 8 8 9 9,5 1,5 10 1,2 0,6 9 9,5 1,5 10 10,5 10,5 12 I2t ON 1 12 102 T4 10-3 10-1 1 10 x In 1 T6 T5 T5 T6 400 630 630 800 1000 10 I [kA] Note: The dotted curve of function L corresponds to the maximum delay (t1) which can be set at 6xl1, in the case where 320 A CTs are used for T4 and 630 A for T5.

For T4 In = 320 A, T5 In = 630 A and T6 In = 630 A ⇒ I3 max = 10 x In. Only the electronic settings are available. 9-1 In disabled at 8 In t=k 10-1 10-1 T7 S,H,L t=k T7 V 10-2 10-2 10-3 10-3 10-1 10 1 10 x In 102 I [kA] 10-1 1 10 10 2 I [kA] For T7 In = 1250 A, 1600 A ⇒ I3 max = 12 x In. 13 0,5 0,4 103 102 0,7 0,95 0,6 0,8 1 0,9 1,5 t [s] t [s] 2 D C 102 10 B 4 A 6 8 D C 101 1 10 12 B A 1 10-1 10-2 10-3 10-1 10 1 10 2 I [kA] 10-2 10-1 1 1,05 101 Note: for PR211/P-I releases, consider the curves relevant to function I only.